WALL INSULATION
AIR-CELL Insuliner is the latest in thermo reflective insulation technology with the most advanced fire performance characteristics, achieving a Group 2 classification to NCC fire ratings for wall and ceiling linings. It comprises a cross-linked, closed-cell insulation core sandwiched by highly reflective foil facings. AIR-CELL Insuliner is strong, tough & durable, and a 3-in-1 vapour barrier and radiant barrier reflective insulation designed for warehouses and commercial or industrial sheds.
Product Highlights
Roll Size
1350 mm x 22.25 m (30 m2)
Roll Diameter
400 mm
Nominal Product Thickness
5.5 mm
Roll Weight
9 kg
Max. Span Distance
1200 mm under sheet roof without support mesh
Fire Performance
| Characteristic | Standard | Classification |
| NCC Group Number | AS ISO 9705 | Group 2 |
| Flammability Index | AS 1530.2 | ≤ 5 |
| Fire Propagation | BS476 – 6 | Class 0 |
| Surface Spread of Flame | BS 476 – 7 | Class 1 |
| Surface Burning | UL 723 | Class A |